ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC TITLE 32 TEMPORARY NTE 1 NOV 2027
Army National Guard Units
THIS IS A TEMPORARY NATIONAL GUARD TITLE 32 EXCEPTED SERVICE POSITION. This National Guard position is for a ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC TITLE 32 TEMPORARY NTE 1 NOV 2027, Position Description Number D1201000 and is part of the NH ARNG CSMS, National Guard. This vacancy is to gather applications that may or may not result in a referral or selection.
The primary purpose of this position is to perform calibration, diagnostics repair, and certification of electronic, mechanical, and radiation Test Measurement and Diagnostic Equipment (TMDE). Sets up system test sets and various types of test equipment such as frequency meters, standing wave ratio meters, radio frequency (RF) power meters, function/ arbitrary waveform generator, distortion analyzers, time frequency work stations, oscillators, voltmeters, electronic counters, oscilloscopes, attenuators, decade resistors and capacitors, signal generators, stroboscope, tachometers, pneumatic and hydraulic pressure standards and other physical and electronic tests. Diagnoses equipment, makes repairs, and replaces defective parts/components such as integrated circuits, printed circuit boards, electronic condition coils, radiation detector boards/circuits, crystals, transistors, tubes, transformers, condensers, diodes, relays potentiometers, and related components. Following repair, tests by applying signals in known amplitude and wave shape into oscilloscopes to observe wave pattern. Isolates faults by taking measurements and comparisons in voltage, amperage, ohms, henries, power factor, watts, temperature, humidity, microns, foot-pounds, decibels, sensitivity, noise, stability, Voltage Standard Wave Ratio (VSWR), impedance, phase, absolute pressure, time intervals, displacement, flow rate, etc., to determine performance of equipment. If signal is distorted, traces it through electronic stages to locate malfunctioning part. Checks sweep rate by feeding known signal to an oscilloscope and observing wave pattern to correct shape and size. Operates equipment to complete range checking for proper operation of positioning controls. Adjusts with trimmer potentiometers; and if calibration is still not possible, adds or removes sufficient resistance to permit balancing of circuit. As needed, contacts the using organization to obtain information concerning the nature of the malfunction. Uses equipment schematics to analyze circuits by preparing block diagram showing major components such as amplifiers, filters, oscillators and indicators. Determines purpose in operation characteristics of each major section. Refers to technical manuals and manufactures specifications to obtain information on operation characteristics of circuit components such as integrated circuits, microprocessors, decoders, latching networks, notch filters, logics, controllers, programmable gain amplifiers, digital displays, transistors, tubes, transformers, coils, relays, motors, and similar devices. Disassembles, cleans and inspects parts such as printed circuit boards, resistors, capacitors, integrated circuits, relays, chambers, cables, and wiring for evidence or wear or malfunction. Repairs and/or replaces parts as required. Uses special test devices and radioactive samples or other calibrated sources. Tests equipment for sensitivity and correct operation. Observes necessary precautions as stipulated in operational repair manuals. Makes radiation calculations/readings at various distances from the standard ensuring radiation equipment is operating in specified parameters. Performs contamination/radiation surveys on radiation equipment to control/eliminate radiation leakage/contamination. Completes necessary Army Maintenance Management System (TAMMS), calibration, radiation reports and other records and forms on work completed. Ensures maximum number of weapons systems are operationally ready. Uses TMDE Integrated Maintenance Management Systems (TIMMS) for all supported equipment to track, turn-in, repair, calibrate, and return to the end user in a timely fashion to prevent work stoppages. Furnishes technical data to the supervisor for inclusion in reports as well as recommending equipment improvement and solutions for unusual problems related to testing and the use of precision TMDE.
Compatible military grade and assignment required prior to the effective date of placement. This is a Title 32 TEMPORARY excepted service position that requires membership in a compatible military assignment in the employing state's National Guard. Military Grades: Enlisted E2 to E8 Selectee(s) must be within the military grade(s) listed in this job announcement prior to the effective date of placement into the technician position. Applicant(s) (Enlisted) who are over grade must clearly state, in their resumes, their intentions to willingly take a reduction in grade. Compatible Military Assignments: 88. 91, 94 GENERAL EXPERIENCE: Experience or training which demonstrates a working knowledge of electronic principles involved in the generation and measurement of such elements as voltage, current, impedance, capacitance, frequency, and inductance. Experience in the use of various precision measurement instruments and standards. SPECIALIZED EXPERIENCE: Must have experience or training with basic application of operating principles such as the production and utilization of oscillations over a broad range of frequencies; signal and waveform behavior, distortion, and amplification; pulse, trigger, and synchronization techniques; digital/analog processing and data conversion techniques; and a variety of display and indication methods. Experience in tracing signals and voltage paths, and skilled in the analysis of waveform characteristics such as timing, duration, frequency, and phasing. Originates test set-ups to isolate malfunctions and check performance characteristics of special or unique test panels or mockups. Experience in interpreting and applying a variety of technical electronic information such as schematic symbols, mathematical expressions and formulas, calibration procedures, and other reference materials. Experience in applying established techniques and methods of repair, testing, alignment, and calibration of equipment, which serves as test equipment or precision measurement standards. Experience in utilizing electronic circuits to measure electronic or electrical quantities to determine the performance characteristics and accuracy of other instruments and equipment. It is not necessary for applicants to possess the MOS/AFSC listed as compatible to the position in order to apply, however applicant must meet the qualifications for the position. It is applicant's responsibility to acquire a compatible MOS/AFSC within 1 year of appointment. Coordinate with your unit's training representative to determine whether or not you can qualify for a specific MOS/AFSC and/or receive training within the 1 year timeframe before excepting the position.
Bu ilan USAJOBS kaynağından doğrulandı. Başvuru özgün kaynakta tamamlanır.
Özgün ilanda başvur ↗
Bu ilanda sorun mu var?